MDE-4549 Gasboy CFN Series WEX Special Card Handler V003 · February 2006 Page 3
Overview
Overview
When a card is swiped, the special handler identifies if this is a WEX card that needs to be
handled by a special lockout routine.
WEX cards that match the ISO list are converted into a Gasboy
®
supervisor club card format
(Figure 1) as follows (when converted, WEX Product Restriction = Gasboy Auth. and WEX
Product ID = Gasboy Restriction):
The first 6 digits are to be manually entered (the prompt is determined by trfmt
configuration (see “TRFMT” on page 5) and this 6-digit manually-entered number can be
locked out using the site lockout.). If not entered, the first 6 digits are set to 000999.
The next 5 digits are the vehicle number from the WEX card. The 5-digit vehicle number
becomes the second club card field
The 6-digit fleet number will be the third club card field.
WEX club cards where the number of digits on the card does not equal the number of digits in
SYS-PAR will have the fields zero-filled at the end of the card number.
The WEX fleet number is checked by one of the two following methods:
•If the fleet.dta file exists, the fleet number is checked against the fleet.dta positive
lockout file on the E:drive.
When using the fleet.dta file, you can turn off the restriction code by adding 1- or 2-digit
mask to the end of each fleet number you want to affect in the fleet.dta file. This 1- or 2-
digit mask will be at the end of the fleet number making it look like a 7-digit number, or
can be separated by a comma, or other character (123456,2). In this instance, a fleet
number ends with a 2, the vehicle restriction is turned off and there will be no prompt.
•If the fleet.dta file does not exist, the fleet number is checked against either of the two
system IDs.
Then the 5-digit vehicle number followed by the 6-digit fleet number of the WEX card is
checked against the WEX.DTA negative lockout file located on the PCMCIA RAM Card, E:
Drive (F: if there is no E: Drive found) or the RAM Drive (R:) if a CFN III. If the number is
found, the cards are invalid.
The WEX.DTA file is a sorted, ASCII file and is limited to 20,000 11-digit records. If no
WEX.DTA file exists, a prompt of “down try later” will be displayed.
Figure: 1 - Gasboy Supervisor Club Card Format
12345612345123456
6-digit manually-entered number (or 000999)
5-digit vehicle number from WEX card
6-digit fleet number from WEX card